HERMLE Z 206 A INSTRUCTION MANUAL Pdf Download (2024)

  1. Manuals
  2. Brands
  3. Hermle Manuals
  4. Laboratory Equipment
  5. Z 206 A
  6. Instruction manual

Compact centrifuge

Hide thumbs Also See for Z 206 A:

  • Operating manual (40 pages)
1
Table Of Contents 2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
  • Contents
  • Table of Contents
  • Troubleshooting
  • Bookmarks

Table of Contents

  • Table of Contents

  • 1 Product Description
    • Usage in Accordance with Safety Standards

      • General Information

        • Hazards and Precautions

        • Brief Description

        • Safety Standards

        • Warranty

    • Installation

      • Installation of the Centrifuge

        • Unpacking the Centrifuge

        • Space Requirements

        • Installation

    • Technical Data

    • Conformity Declaration

  • 2 Operation
    • Installation of Rotors

      • Mounting and Loading Angle Rotors

      • Mounting and Loading Swing out Rotors

      • Overloading of Rotors

      • Removing the Rotors

    • Operation

      • Power Switch

      • Lid Release

      • Lid Lock

      • Pre-Selection of Speed/Rcf-Value

      • Pre-Selection of Running Time

      • Pre-Selection of Brake Intensity and Acceleration

      • Starting the Centrifuge

    • Safety Features

      • Imbalance Detection

  • 3 Maintenance
    • Service and Maintenance

      • Maintenance and Cleaning

      • Glass Breakage

      • Disinfection of PP-Rotors

  • 4 Trouble Shooting
    • Error Messages: Cause / Solution

    • Survey of Possible Error Messages and Their Solutions

      • Lid Release During Power Failure

      • Discription of the Error Message System

      • Error Messages

Advertisem*nt

Quick Links

  • 1 Error Messages: Cause / Solution
  • 2 Error Messages
  • Download this manual

See also: Operating Manual

Instruction Manual

For

Compact Centrifuge

Z 206 A

Page 1 of 24

INSTRUCTION MANUAL Z 206 A

www.bioecoms.com

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

HERMLE Z 206 A INSTRUCTION MANUAL Pdf Download (1)

Related Manuals for Hermle Z 206 A

  • Laboratory Equipment Hermle Z 206 A Operating Manual

    (40 pages)

  • Laboratory Equipment hermle z233 m-2 Instruction Manual

    Microcentrifuge (20 pages)

  • Laboratory Equipment Hermle Z 207 A Operating Manual

    Small centrifuge (40 pages)

  • Laboratory Equipment Hermle Z 233 M-2 Instruction Manual

    Microliter centrifuge (24 pages)

  • Laboratory Equipment Hermle Z 207 MK User Manual

    (44 pages)

  • Laboratory Equipment Hermle Z 287 A Operating Manual

    Universal centrifuge (44 pages)

  • Laboratory Equipment Hermle Z 216 M User Manual

    (44 pages)

  • Laboratory Equipment Hermle Z 207 M User Manual

    (40 pages)

  • Laboratory Equipment Hermle Z 216 MK Operating Manual

    Refrigerated micro centrifuge (48 pages)

  • Laboratory Equipment Hermle Z 207 H User Manual

    (40 pages)

  • Laboratory Equipment Hermle Z 160 M Instruction Manual

    Microlitre centrifuge (10 pages)

  • Laboratory Equipment Hermle Z 306 Service Manual

    Universal centrifuge (52 pages)

  • Laboratory Equipment Hermle Z 300 K Instruction Manual

    Refrigerated bench top centrifuge (22 pages)

  • Laboratory Equipment Hermle ZK 496 User Manual

    (52 pages)

  • Laboratory Equipment Hermle Z 366 Operating Manual

    Universal table top centrifuge (48 pages)

  • Laboratory Equipment Hermle Z 167 M Operating Manual

    (40 pages)

Summary of Contents for Hermle Z 206 A

  • Page 1 Instruction Manual Compact Centrifuge Z 206 A Page 1 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 2: Table Of Contents

    4.1 Error messages: Cause / Solution 4.2 Survey of possible error messages and their solutions 4.2.1 Lid release during power failure 4.2.2 Discription of the error message system 4.2.3 Error messages Page 2 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 3: Usage In Accordance With Safety Standards

    For your personal safety, please review the following precautions: • The HERMLE Z 206 A is not explosion-proof and must therefore not be operated in explosion- endangered areas or locations. During centrifugation, it is prohibited to stay within the safety zone of 30 cm around the centrifuge or deposit hazardous substances within this area.
  • Page 4: Brief Description

    1.1.1.2 Brief description Model Z 206 A is a compact small centrifuge capable of running swing out and angle rotors. All relevant run parameters can easily be set with the display keys and be pre-selected with the main adjustment knob. All pre-selected and actual values are permanently displayed on large LCD display.
  • Page 5: Warranty

    1.2 Installation 1.2.1 Installation of the centrifuge 1.2.1.1 Unpacking the centrifuge Model Z 206 A is supplied in a carton. Remove the strap retainer, open the carton and remove the centrifuge. The instruction manual should always be kept with the centrifuge.
  • Page 6: Installation

    VDE 0871, Funkentstörgrad B Test obligations To be filled in by purchaser: Inventory-No.: Check-No.: Location: Maintenance contract: Your service department Labnet International PO Box 841, Woodbridge, NJ Ph: 732-417-0700 Your agent Page 6 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 7: Conformity Declaration

    DIN EN 61 010-1; DIN EN 61 010-2-020; EN 50501/B; EN 61000-6-1; EN 61000-3-2; EN 61000-3-3; EN 292-2; EN 292-2/A1; EN 61326; 73/23/EWG; 98/37/EG; 98/79/EG Wehingen/Germany, 1st January 2007 Harald Hermle President Page 7 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 8 (See photo 1) To set the data in the unit please wait until the indication in the display “rpm/rcf” disappears. Now all important rotor parameters for the centrifuge are stored. Photo 1 Page 8 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 9 Please notice that you must enter the program as described under point 1.5.1 to change the adjustments of the points 1.5.2. After you have stored the settings you can return to the standard program mode again by switching off and the switching on the centrifuge. Page 9 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 10 The first two numbers (X) indicate the quantity of errors ongoing from 00 to 99, the last two numbers (Y) indicate the error code (ex. 02 = imbalance sensor is defective). Photo 3a Photo 3b Page 10 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 11: Operation

    Be sure that the rotor is fully installed on the motor shaft. Photo 4 Photo 5 ATTENTION: For safety always ensure that rotor fixing screw is tightened before each run. (see photo 5) Page 11 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 12 For safety always ensure that rotor fixing screw is tightened before each run. (see photo 6) It is allowed to operate a 12-place-rotor with 2 or 4 loaded tubes only. But the loaded borings must be opposite each other. Photo 7: incorrect Photo 8: correct Page 12 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 13: Mounting And Loading Swing Out Rotors

    Make sure that the unloaded buckets also be put inside the rotor (see photo 9 and 10). ATTENTION: Always fill all rotor positions with rotor buckets. Photo 9: incorrect Photo 10: right Page 13 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 14: Overloading Of Rotors

    The power switch is located on the bottom, left side of the unit. Photo 11 Attention: After turning on the power switch you must open the lid of the unit first, prior starting the centrifuge. Page 14 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 15: Lid Release

    As a sign that the centrifuge is ready for operation the display reads ‘rpm/rcf“ the word “close“ (8). Simultaneously it appears in that display the word “rotor“ (10), as well as the code number of the rotor, which is in the centrifuge ex. “nr 96“ (11). Page 15 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 16: Pre-Selection Of Speed/Rcf-Value

    It is the same with the pre-selection of the RCF-value. The setting range is between 20 xg and the maximum permissible centrifugal force of the rotor. The maximum speed of the Z 206 A is 6000 rpm resp. 4180 xg. Photo 13...
  • Page 17: Pre-Selection Of Running Time

    “h : m“. After exceeding of 99 hours 59 min the word “cont” appears in the display “time”. That continuous run can only be interupted by pressing the key “stop” (2). The display shows always the remaining running time. Photo 14 Page 17 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 18: Pre-Selection Of Brake Intensity And Acceleration

    Now the desired brake intensity can be pre-selected by the adjusting knob (7). The value 9 is equivalent to the shortest and the value 0 to longest possible brake time. Photo 15 Acceleration and deceleration times Z 206 A(120 V / 230 V) in seconds Acceleration values Deceleration values...
  • Page 19: Starting The Centrifuge

    By the “stop“ key (2) you can interrupt the run at any time. After pressing the key the centrifuge decelerates with the respective pre-selected intensity down to stand still. Photo 17 Page 19 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 20: Safety Features

    Load the rotor as described in chapter 2.1.1. When in the display “time” the word “error” together with the number “02“ (18) appear, there could be following reasons: • The imbalance switch is defective. Photo 18 Page 20 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 21: Maintenance

    The maintenance procedure should be repeated every 10 to 15 runs, but at least once a week. Page 21 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 22: Glass Breakage

    ATTENTION: Because the temperature may rise during the sterilization, rotors, boxes and bottles must not be closed respectively must be totally unscrewed. Chemical sterilization Bottles, boxes and rotors may be treated with the usual liquid disinfectants. Page 22 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 23: Trouble Shooting

    ATTENTION: Don’t put your hands in the rotor chamber as long as the rotor is still spinning! • When completed, push the plastic stopper back in the unit again. (see photo 19) Photo 19 Page 23 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
  • Page 24: Discription Of The Error Message System

    Leap of speed is too big between measurements Motor Error Open lid while the motor is running Lid contact defective Overspeed Undervoltage in the intermediate circuit Blackout of the relay Page 24 of 24 INSTRUCTION MANUAL Z 206 A www.bioecoms.com...
HERMLE Z 206 A INSTRUCTION MANUAL Pdf Download (2024)
Top Articles
Latest Posts
Article information

Author: Stevie Stamm

Last Updated:

Views: 6425

Rating: 5 / 5 (80 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Stevie Stamm

Birthday: 1996-06-22

Address: Apt. 419 4200 Sipes Estate, East Delmerview, WY 05617

Phone: +342332224300

Job: Future Advertising Analyst

Hobby: Leather crafting, Puzzles, Leather crafting, scrapbook, Urban exploration, Cabaret, Skateboarding

Introduction: My name is Stevie Stamm, I am a colorful, sparkling, splendid, vast, open, hilarious, tender person who loves writing and wants to share my knowledge and understanding with you.